Expanding the Operator Interface (BE1) 08/2005
7 Configuring and Working Environment
© Siemens AG, 2005. All rights reserved
BE1/7-154 SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
Display axis names, general solution
HMI Embedded, HT6 and HMI Advanced:
NC access to relevant machine data, string functions.
Maximum text lengths
Long text for standard screen size 62 characters or 25 characters for HT6
Screen form header 21 characters or 12 characters for HT6
7.2 HMI Embedded and HT6
Central control file COMMON.COM
This file contains information relating to:
• Assignment between start softkeys and configuration files
• Assignment of user keys to configuration files (only relevant for HT6)
• Assignment of display numbers to configuration files in PLC interface DB19
• Control entries (size of LOG file, available memory on RAMDRIVE for
configuration files, search criteria for language-dependent texts, search criterion
for configuration files).
Details of how to make the appropriate entries in file COMMON.COM for the HMI
Embedded and HT6 can be found in the next section.
Changes to COMMON.COM only take effect following a restart.
Storage location
The central control file COMMON.COM must be stored in one of the following NC
directories:
• \CMA ;Manufacturer cycles directory
• \COM ;Comment directory
• \CST ;Standard cycles directory
• \CUS ;User cycles directory
The system searches through the directories for COMMON.COM in the following
order. The first file with this name is evaluated.
The files with the configured form definitions must be stored:
• in one of the three directories specified above
• In the Flash memory of HMI Embedded and HT6
(the DOS file name conventions apply here) BIN directory
File names
All file names must follow DOS conventions (xxxxxxxx.eee).
Size of display files
The total size of the file with compressed images CST.ARJ is 150 kB.
In the case of HMI Embedded, 100 kB of this is used by the system.