Commissioning HMI Advanced (IM4) 08/2005
5 HMI software on PC
© Siemens AG, 2005. All rights reserved
IM4/5-166 SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
5.1 Installing HMI Software on a PC
Requirements
Target system Standard PC with
600 MHz, 256 MB RAM
Available hard disk space: 500 MB
Operating system MS Windows XP Professional
MPI driver Version 6
NC interface (SINUMERIK powerline) CP5511, CP5611
NC interface (SINUMERIK solution line) Network connection (Ethernet)
"Small fonts" must be selected under "Control Panel/Display, Settings".
Software
• Name: HMI Advanced for PC/PG
• Installation language: German/English
• Distribution medium CD
• Uninstallable Yes
Operating sequence
1. Insert the CD in the CD drive
2. Start setup.exe
3. Select language
4. Specify the target directory: Any
5. For SINUMERIK powerline, select:
- Online with communication to NC
- The system asks whether you wish to install the MPI drivers
- Local without communication to NC, with NC simulation
6. For SINUMERIK solution line, select:
- Online with communication to NC
7. The system lists all the entries you have made
8. On confirmation the copy operation starts
9. At the end of the copying operation, you are prompted to restart the PC.