Commissioning HMI Advanced (IM4) 08/2005
2 Functions/Parameterization
© Siemens AG, 2005. All rights reserved
IM4/2-76 SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
2.4.13 Configuring the "EXIT" Softkey
Application
If you want the sequence control of the HMI software to support an “EXIT” softkey,
you should make the following settings:
[Miscellaneous]
ExitButton=True
ExitButtonIndex = index
The text for identifying the softkey text must be entered in
F:\mmc2\language\re_xx.ini where xx is the language identifier.
ExitButtonAccessLevel=7 ; Dialog box to ask user
ExitButtonQueryUser = True
Requesting a RESTART after shutdown (for Windows XP only)
This function enables HMI Advanced (including Windows XP) to be shut down
followed by a reboot of the PCU during the setup phase. This enables you to avoid
switching the PCU or machine on and off.
The following settings are required:
[Miscellaneous]
EnableRebootDialog=True
The entry can be set either directly in the INI file or by means of the user interface
via Start-up → HMI → Settings → HMI Exit Mode. If the “EXIT” menu is configured
accordingly, the “Shutdown... " or "Restart ... " prompt appears depending on the
access stage.
• If the protection level is lower than the manufacturer level (protection level 2
to 7) or if the above entry is set to "False" in the REGIE.INI file, the prompt
can be confirmed with:
OK HMI is closed and Windows XP is shutdown.
Cancel HMI is not closed
• If you have the applicable access authorizations (protection level 2 to 7), the
following option is offered:
Restart HMI and Windows XP are closed and then
restarted.
Exit HMI is closed and Windows XP is shutdown.
Cancel HMI is not closed