08/2005 Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
IM4/2-83
IsoActive=0
; 1: ask before overwriting CFG_RESET.INI, 0: don't ask
Ask_for_CFG_RESET.INI=0
; Directory to store ISO-formatted programs from
; ISO paper tape archive
; Not changeable by user interface (supported if IsoActive=1)
ISO-Path=/_N_WKS_DIR/_N_SHOPMILL_WPD
; writing ISO paper tape archive:
; 1: accept ISO programs only in ISO path,
; 0: accept in all directories
; Not changeable by user interface (supported if IsoActive=1)
AcceptOnlyISO-Path=1
; 1: first unpack and then delete ZIP files while reading
; an IBN archive,
; 0: don't unpack, but store ZIP files in database
; not changeable by user interface
UnPack=1
; time to wait after a PLC memory reset in seconds
Wait for PLC=20
; reading internal pc-formatted archive that is not a setup archive:
; 0: destination of the unpacked files is determined through any
; existing files with same name, if no such file exist destination
; is MMC
; else: destination is determined from the file header, i.e. from the
; location where the file was read from
TakeDestinationFromHeader=0
2.5.4 DG.INI
Softkey access in the Diagnostics operating area can be set individually by
entering the protection level. Enter the required protection level in the DG.INI file in
section
[ACCESSLEVEL]
ALARMS=7 ; Alarms
SERVICE=7 ; Service displays
COMMUNIC-LOG=3 ; Communication log
PLC=3 ; PLC status
PLC-CHANGE=2 ;PLC status:
; Softkey change value, softkey reset value
; Softkey commit value
; Locked by manufacturer
REMOTE-DIAGNOSIS=4 ; Remote diagnosis