08/2005 Starting Up HMI Embedded (IM2)
3 Communication/Initial Requirements
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
IM2/3-23
Server name (setting not mandatory)
In order to assign symbolic names to the computers, the relevant nodes to be
addressed within the network can be entered so that their names can be resolved:
Example
Server name:
192.168.0.20 R2345
192.168.0.21 R2346
With these settings computers R2345 and R2346 can be addressed by means of
their symbolic names.
Fig. 3-3 Server names
Operation:
The first entry in the line is the IP address.
The second entry is the computer name. The data already specified appears in the
upper section of the screen.
By selecting the "New" and "Edit" softkeys you can go to the lower half of the
screen where you can edit entries.
You can change back to the upper section by pressing the "Abort" softkey (data is
not saved) or the "Save" softkey (data is saved).
With external drives (network connections) you need to specify the full network
path (Computer name\\Share name\\Path specification
), whereby the path name is
optional:
\\R4711\Workpieces\Template
\\R4812\Workpieces
These names must be available on the network computer. The network computer,
for example, is called "\\R4812". The share name WORKPIECES must be specified
on any hard disk drive on this computer.

Table of Contents

Other manuals for Siemens SINUMERIK 840D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840D and is the answer not in the manual?

Siemens SINUMERIK 840D Specifications

General IconGeneral
SeriesSINUMERIK 840D
AxesUp to 31
ChannelsUp to 10
Operating SystemWindows-based
Power Supply24 V DC
Control Unit TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
InterpolationSpline
PLCIntegrated PLC
Data StorageCompactFlash, USB