EasyManua.ls Logo

Sony CBK-HD01 - Page 143

Sony CBK-HD01
300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-53
PDW-700/V1 (E)
AUTO SHADING Display (Automatic SHADING adjustment)
Item Setting Function
AUTO BLK SHADING _ Executes the auto black shading function
RESET BLK SHD _ Clears black shading compensation values
TEST OUT SELECT VBS/Y/R/G/B/LCD Selects the video signal that is output from the TEST
OUT and the VBS/SDI OUT connector (Invalid when
the BARS signal is selected)
(The Y-signal becomes the VBS signal when VBS is
selected in the SD REAR BNC OUT of the OUTPUT
SEL display (of the OPERATION menu) and SD is
selected in the TEST OUT SELECT). The output
signal returns to the Y-signal without fail at power-on
MASTER GAIN(TMP) _6/_3/0/3/6/9/12/18/ Temporarily sets the master gain value
24/30/36/42 dB
APR Display (Detect compensation function)
Item Setting Function
APR _ Executes the defect compensation function
APR (SLS)
*
_ Suppresses white flecks in SLS (Slow Speed Shutter)
mode by executing the automatic pixel noise reduction
function
n
The execution time for this function is about 30 minutes.
More time may be required when temperatures inside
the unit are low.
APR PRESET _ Deletes white flecks data that was added by execution
of the APR and automatic black balance adjustment
functions
* : This does not appear when SYSTEM LINE is set to 720, SYSTEM FREQUENCY is set to 59.9P, and SCAN MODE is set to 23.9P.
M21 AUTO SHADING TOP
AUTO BLK SHADING: EXEC
RESET BLK SHD : EXEC
TEST OUT SELECT : VBS
MASTER GAIN(TMP): 0dB
M22 APR TOP
APR : EXEC
APR(SLS) : EXEC
APR PRESET : EXEC