Intelligently monitored and fall-proof
The SE6 safety module reports to the controller if a brake test is required according to its respective time configuration. The controller can
exit the ongoing process within the projected tolerance time and start a brake test. If the test is successful, the controller resumes normal
operation until the safety module requests the next brake test when the configured time has expired.
P1
P2
F1
F2
S1
S2
F1
F2
P1
P2
P1
P2
P1
P2
a
b
c
d
e
Severity of
injury
Frequency and/
or duration of
the hazard
Possibility of
avoiding the
hazard or
limiting the
damage
PLr –
Required
Performance
Level
S1: Light/
reversible
S2: Serious/
irreversible
F1: Rarely/short
F2: Frequently/long
P1: Possible
P2: Hardly possible
Low
High
Contribution to risk minimization
Start
SD6 drive controller and SE6 safety module: Your advantages
• Powerful stand-alone drive controller with advanced safety technology
• Optional CANopen, EtherCAT or PROFINET communication
• Extensive stop and movement functions such as SS1, SS2, SDI, SLI, SLS, SOS, SSR or SLP
• Safe control (SBC) and safe testing of up to two brakes with automatic test cycle monitoring
• Application-specific stopping of the drives if a limit value is exceeded or for an emergency stop
• Alternative controller- or drive-controlled stop ramps with SS1 and SS2
Additional documentation
Additional documentation related to the product can be found at
http://www.stoeber.de/en/downloads/
Enter the ID of the documentation in the Search field.
Documentation ID
SD6 drive controller manual 442425
SE6 safety module manual 442795
418