3.5.5 Other product features
Feature Value
Max. permitted gear unit temperature (on the surface of the gear unit) ≤ 90°C
Paint Black RAL 9005
Explosion-proof design in accordance with (ATEX) Directive 2014/34/EU
(optional)
Not available
Efficiency:
η
get
single-stage
η
get
two-stage
96%
93%
Protection class:
1
Gear unit
Motor
IP65
IP56, optionally IP66
3.5.6 Direction of rotation
The input and output rotate in the same direction.
3.6 Project configuration
Project your drives using our SERVOsoft designing software. Download SERVOsoft for free at https://
www.stoeber.de/en/ServoSoft.
It is the most convenient and reliable method of drive selection, as the entire torque/speed curve of the ap-
plication is displayed and evaluated here in the curve of the geared motor.
In this chapter, only limit values for specific operating points can be taken into consideration for manual
drive selection.
An explanation of the formula symbols can be found in Chapter Symbols in formulas.
The formula symbols for values actually present in the application are marked with *.
1
Observe the protection class of all the components.
3.6 Project configuration 3 PHplanetary geared motors
54