PROF. 1 (path: MENU / INPUT / LOGGER SETUP / CHANNEL 2 / CHAN. 2 PROF. 1) sub-list was
selected, up to five words are written in the given sequence:
<result1> - PEAK result in the case of VLM or in the case of SLM if the first position was marked,
else no value is written;
<result2> - P–P result in the case of VLM or MAX result in the case of SLM if the second position was
marked, else no value is written;
<result3> - MAX result in the case of VLM or MIN result in the case of SLM if the third position was marked,
else no value is written;
<result4> - RMS result in the case of VLM or in the case of SLM if the fourth position was marked, else no
value is written;
<result5> - VDV result in the case of VLM if the fifth position was marked, else no value is written;
• results of the measurement from the 1
st
profile of the 3
rd
channel if the LOGGER MODE was set to ON
(path: MENU / INPUT / LOGGER SETUP / LOGGER MODE:ON) and if any position in CHAN. 3
PROF. 1 (path: MENU / INPUT / LOGGER SETUP / CHANNEL 3 / CHAN. 3 PROF. 1) sub-list was
selected, up to five words are written in the given sequence:
<result1> - PEAK result in the case of VLM or in the case of SLM if the first position was marked,
else no value is written;
<result2> - P–P result in the case of VLM or MAX result in the case of SLM if the second position was
marked, else no value is written;
<result3> - MAX result in the case of VLM or MIN result in the case of SLM if the third position was marked,
else no value is written;
<result4> - RMS result in the case of VLM or in the case of SLM if the fourth position was marked, else no
value is written;
<result5> - VDV result in the case of VLM if the fifth position was marked, else no value is written;
• results of the measurement from the 1
st
profile of the 4
th
channel if the LOGGER MODE was set to ON
(path: MENU / INPUT / LOGGER SETUP / LOGGER MODE:ON) and if any position in CHAN. 4
PROF. 1 (path: MENU / INPUT / LOGGER SETUP / CHANNEL 4 / CHAN. 4 PROF. 1) sub-list was
selected, up to five words are written in the given sequence:
<result1> - PEAK result in the case of VLM or in the case of SLM if the first position was marked,
else no value is written;
<result2> - P–P result in the case of VLM or MAX result in the case of SLM if the second position was
marked, else no value is written;
<result3> - MAX result in the case of VLM or MIN result in the case of SLM if the third position was marked,
else no value is written;
<result4> - RMS result in the case of VLM or in the case of SLM if the fourth position was marked, else no
value is written;
<result5> - VDV result in the case of VLM if the fifth position was marked, else no value is written;
• results of the measurement from the 2
nd
profile of the 1
st
channel if the LOGGER list was marked and
LOGGER MODE was set to ON (path: MENU / INPUT / LOGGER SETUP / LOGGER MODE:ON) and
if any position in CHAN. 1 PROF. 2 (path: MENU / INPUT / LOGGER SETUP / CHANNEL 1 /
CHAN. 1 PROF. 2) sub-list was selected, up to four words are written in the given sequence:
<result1> - PEAK result in the case of VLM or in the case of SLM if the first position was marked,
else no value is written;
<result2> - P–P result in the case of VLM or MAX result in the case of SLM if the second position was
marked, else no value is written;
<result3> - MAX result in the case of VLM or MIN result in the case of SLM if the third position was marked,
else no value is written;
<result4> - RMS result in the case of VLM or in the case of SLM if the fourth position was marked, else no
value is written;