The threshold level influences the calculations of the dosimeter results, namely
DOSE, D_8h and LAV. The Threshold Level line is accessible after pressing
the / key in the Dosimeter Setup list. The available values are as follows:
None, 75 dB, 80 dB, 85 dB or 90 dB.
The exchange rate influences the calculations of the dosimeter results, namely
DOSE, D_8h and LAV. The exposure rate equal to three complies with
ISO R 1999 “Assessment of Occupational Noise Exposure for Hearing
Conservation Purposes”, while equal to five - complies with the American
“Occupational Safety and Health Act” OSHA. The Exchange Rate line is
accessible after pressing the key in the Dosimeter Setup widow. The
available values are as follows: 2, 3, 4 or 5.