Notifications and Errors 157
30 Notifications and Errors
Operating and error notifications can be shown in the operating terminal display.
30.1 Operating Notifications
In AUTOMATIC MODE, operating notifications appear at the lower edge of the menu win-
dow in blue. The notification will automatically disappear when the cause is resolved.
Notification Description
No automatic auxiliary signal The HIGH signal is expected at the automatic auxili-
ary signal input of the automation interface. However,
the signal is not present.
Check settings: see Chapter 26.7.5 "Automatic auxili-
ary signal" on page 134.
Check connection or peripherals: see Chapter 31.5
"Control procedure information" on page 164.
Waiting for pad safety signal The HIGH signal is expected at the pad safety input
of the automation interface. However, the signal is not
present.
Check settings: see Chapter 26.7.1 "Pad safety" on
page 131.
Check connection or peripherals: see Chapter 31.5
"Control procedure information" on page 164.
Pad cleaning active The machine is carrying out a pad cleaning cycle.
Homing active The machine is moving to the home position.
Printer not in home position The machine is not in the home position.
Homing needs to be carried out: see Chapter 23.3
"Home position" on page 114.
Automatic active A print cycle is carried out in automatic mode.