Appendix A SCPI Command Reference
MEASure subsystem
WCDMA Options Version 6.20
335
:
MEASure:WCDMa[:CONTinuous]:RFTX:POWer:PEAK
:MEASure:WCDMa[:CONTinuous]:RFTX:NSTair[:DATa]
:MEASure:WCDMa[:CONTinuous]:RFTX:NSTair:POWer
:MEASure:WCDMa[:CONTinuous]:RFTX:ZSPan:POWer
Example
:MEA:WCDMA:RFTX:POW:MEAN?
Starts an RF power measurement and returns the result (in dBm), e.g.
-45.3.
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:POWer:PEAK
Parameters
There are no parameters.
Description
This command starts a continuous measurement of the mobile's peak output power.
To read out the latest measurement result, use the
FETCh:WCDMa:RFTX:POWer:PEAK command
.
Query
This query command will start the measurement and return a result value as soon as
the first measurement has been completed. The result delivered back will contain one
floating-point number in dBm.
Example
:MEAS:WCDM:RFTX:POW:PEAK?
Starts the Peak RF power measurement and returns the result, e.g. -36.8
.
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:NSTair[:DATa]
Parameters
There are no parameters.
Description
This command starts a continuous measurement of the staircase measurement. To
read out the latest measurement result, use the FETCh:WCDMa:RFTX:NSTair?
command.
Query
This query command will start the measurement and return a result value as soon as
the first measurement has been completed. The result delivered back will contain 512
floating-point numbers in dBm.
Example
:MEAS:WCDM:RFTX:NST?
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:NSTair:POWer
Parameters
There are no parameters.
Description
This command starts a continuous measurement of the staircase power measure-
ment. To read out the latest measurement result, use the
FETCh:WCDMa:RFTX:NSTair:POWer? command.
Query
This query command will start the measurement and return a result value as soon as
the first measurement has been completed. The result delivered will contain
7 floating point numbers in dBm.
Example
:MEAS:WCDM:RFTX:NST:POW?
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:ZSPan:POWer

Table of Contents