Appendix A SCPI Command Reference
MEASure subsystem
334 WCDMA Options Version 6.20
:MEASure:WCDMa[:CONTinuous]:RFTX:STOP
:MEASure:WCDMa[:CONTinuous]:RFTX:FREQuency
:MEASure:WCDMa[:CONTinuous]:RFTX:POWer:MEAN
Description
Performs the peak current consumption measurement for a specific number of times
(set with the int1 parameter). To read out the latest measurement results, use the
:FETCh:PSUP:PCUR command.
Query
The query form of this command starts the measurements for a specific number of
times (set with the int1 parameter). The returned string contains int1 floating
point values representing the peak current consumption in mA.
Example
:MEASure:ARRay:PSUP:PCUR? 3
In this case, the peak current consumption measurement is performed three times. As
soon as all measurements have been completed and all measurement results
obtained, a string will be delivered back containing the three measurement result val-
ues.
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:STOP
Parameters
There are no parameters.
Description
Stops a continuous measurement of the WCDMA RF TX tests.
Note: Stopping the test is not required since a test is automatically stopped when
you start a new test.
Query
The query form of this command is not available.
Example
:MEAS:WCDM:RFTX:FREQ
:MEAS:WCDM:RFTX:STOP
Configures, starts and stops a measurement.
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:FREQuency
Parameters
There are no parameters.
Description
Starts a continuous measurement of the frequency error.
Query
The query form of this command will start the sequence of frequency error measure-
ments.
Example
:MEAS:WCDM:RFTX:FREQ?
Returns the measured frequency error, e.g.
-7.834.
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:POWer:MEAN
Parameters
There are no parameters.
Description
This command starts a continuous measurement of the mobile's mean output power.
To read out the latest measurement result, use the
FETCh:WCDMa:RFTX:POWer:MEAN command.
Query
This query command will start the measurement and return a result value as soon as
the first measurement has been completed. The result delivered back will contain one
floating point number in dBm.