Appendix A SCPI Command Reference
MEASure subsystem
WCDMA Options Version 6.20
333
:MEASure:ARRay:PSUPply:APOWer
:MEASure:ARRay:PSUPply:ACURrent
:MEASure:ARRay:PSUPply:PCURrent
Example
:MEASure:ARRay:PSUP:ALL? 10
In this case, all power/current consumption measurements are performed ten times.
As soon as all measurements have been completed and all measurement results
obtained, a string will be delivered back containing ten times three measurement
result values.
Syntax
:MEASure:ARRay:PSUPply:APOWer <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for
int1 is 0.
Description
Performs the power consumption measurement for a specific number of times (set
with the int1 parameter). To read out the latest measurement results, use the
:FETCh:PSUP:APOW command.
Query
The query form of this command starts the measurements for a specific number of
times (set with the int1 parameter). The returned string contains int1 floating
point values representing the average power consumption in mW.
Example
:MEASure:ARRay:PSUP:APOW? 3
In this case, the power consumption measurement is performed three times. As soon
as all measurements have been completed and all measurement results obtained, a
string will be delivered back containing the three measurement result values.
Syntax
:MEASure:ARRay:PSUPply:ACURrent <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for
int1 is 0.
Description
Performs the average current consumption measurement for a specific number of
times (set with the int1 parameter). To read out the latest measurement results,
use the :FETCh:PSUP:ACUR command.
Query
The query form of this command starts the measurements for a specific number of
times (set with the int1 parameter). The returned string contains int1 floating
point values representing the average current consumption in mA.
Example
:MEASure:ARRay:PSUP:ACUR? 3
In this case, the current consumption measurement is performed three times. As
soon as all measurements have been completed and all measurement results
obtained, a string will be delivered back containing the three measurement result
values.
Syntax
:MEASure:ARRay:PSUPply:PCURrent <int1>
Parameters
int1 is an integer.
The minimum value for int1 is 0, the maximum value is 100. The default value for
int1 is 0.