Appendix A SCPI Command Reference
MEASure subsystem
342 WCDMA Options Version 6.20
:MEASure:WCDMa[:CONTinuous]:RFTX:CODedomain
:QPOWer[:DATa]
:MEASure:WCDMa[:CONTinuous]:RFTX:CODedomain:QPOWer
:AVG
:MEASure:WCDMa[:CONTinuous]:RFSP:STOP
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:CODedomain:IPOWer
:AVG <Int1>
Parameters
There are no parameters.
Description
Starts a continuous measurement of the code domain power levels of the Q-plane
code channels. To read out the latest measurement result, use
FETC:WCDM:RFTX:COD:QPOW[:DATA] command.
Query
This query command will start the measurement and return a result value as soon as
the first measurement has been completed. The result delivered will contain an array
of 256 floating point numbers.
Example
:MEAS:WCDM:RFTX:COD:QPOW?
Syntax
:MEASure:WCDMa[:CONTinuous]:RFTX:CODedomain:QPOWer:AVG
<Int1>
Parameters
Int1 is an integer. The minimum value for Int1 is 0, the maximum value is 100.
The default value is 0.
Description
Starts a continuous measurement of the code domain power levels of the Q-plane
code channels averaged over <Int1> measurements. To read out the latest
measurement result, use FETC:WCDM:RFTX:COD:QPOW? command.
Query
This query command will start the measurement and return a result value as soon as
<Int1> measurements has been completed. The result delivered will contain an
array of 256 floating point numbers.
Example
:MEAS:WCDM:RFTX:COD:QPOW:AVG 10?
Syntax
:MEASure:WCDMa[:CONTinuous]:RFSP:STOP
Parameters
There are no parameters
Description
Stops a continuous measurement of the WCDMA RF SP tests.
Note: Stopping the test is not required since a test is automatically stopped when you
start a new test.
Query
The query form of this command is not available.
Example
:MEAS:WCDM:RFSP:MSP
:MEAS:WCDM:RFSP:STOP
Configures, starts and stops a measurement.