Appendix A SCPI Command Reference
MEASure subsystem
WCDMA Options Version 6.20
351
:MEASure:WCDMa:ARRay:RFTX:MODQuality:MRMS
:MEASure:WCDMa:ARRay:RFTX:MODQuality:MPEAk
:MEASure:WCDMa:ARRay:RFTX:MODQuality:PHASe:RMS
:MEASure:WCDMa:ARRay:RFTX:MODQuality:PPEAk
Syntax
:MEASure:WCDMa:ARRay:RFTX:MODQuality:MRMS <Int1>
Parameters
Int1 is an integer. The minimum value for Int1
is 0, the maximum value is 100.
The default value is 0.
Description
Performs an RMS magnitude vector error measurement as many times as specified.
Query
The query form of this command will perform the measurement the specified number
of times, and return the results.
Example
:MEAS:WCDM:ARR:RFTX:MODQ:MRMS? 10
Syntax
:MEASure:WCDMa:ARRay:RFTX:MODQuality:MPEAk <Int1>
Parameters
Int1 is an integer. The minimum value for Int1
is 0, the maximum value is 100.
The default value is 0.
Description
Performs a peak magnitude vector error measurement as many times as specified.
Query
The query form of this command will perform the measurement the specified number
of times, and return the results.
Example
:MEAS:WCDM:ARR:RFTX:MODQ:MPEA? 10
Syntax
:MEASure:WCDMa:ARRay:RFTX:MODQuality:PHASe:RMS <Int1>
Parameters
Int1 is an integer. The minimum value for Int1
is 0, the maximum value is 100.
The default value is 0.
Description
Performs an RMS phase vector error measurement as many times as specified.
Query
The query form of this command will perform the measurement the specified number
of times, and return the results.
Example
:MEAS:WCDM:ARR:RFTX:MODQ:PRMS?
Syntax
:MEASure:WCDMa:ARRay:RFTX:MODQuality:PPEAk <Int1>
Parameters
Int1 is an integer. The minimum value for Int1
is 0, the maximum value is 100.
The default value is 0.
Description
Performs a peak phase vector error measurement as many times as specified.
Query
The query form of this command will perform the measurement the specified number
of times, and return the results.
Example
:MEAS:WCDM:ARR:RFTX:MODQ:PPEA? 10