Appendix A SCPI Command Reference
FETCh Subsystem
364 WCDMA Options Version 6.20
:FETCh:WCDMa:RFTX:POWer:MEAN
:FETCh:WCDMa:RFTX:POWer:PEAK
:FETCh:WCDMa:RFTX:NSTair[:DATa]
:FETCh:WCDMa:RFTX:NSTair:POWer
Syntax
:FETCh:WCDMa:RFTX:POWer:MEAN?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The query form returns the latest result value of the
MEASure:WCDMa:RFTX:POWer:MEAN measurement respectively the latest
result values of the MEASure:WCDMa:ARRay:RFTX:POWer:MEAN measure-
ment. The values delivered will contain at least one floating-point number in dBm.
Example
:FETC:WCDM:RFTX:POW:MEAN?
Returns an RF power measurement result, e.g. -45.3
.
Syntax
:FETCh:WCDMa:RFTX:POWer:PEAK?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The query form returns the result of a previous
:MEASure:WCDMa:CONT|ARRay:RFTX:POWer:PEAK measurement. The
values delivered will contain at least one floating-point number in dBm.
Example
:FETC:WCDM:RFTX:POW:PEAK?
Returns the Peak RF power measurement result, e.g.
-36.8.
Syntax
:FETCh:WCDMa:RFTX:NSTair[:DATa]?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The query form of this command returns the latest result value of the
MEASure:WCDMa:CONT|ARRay:RFTX:NSTair measurement. The values
delivered will contain 501 floating-point number in dBm.
Example
:FETC:WCDM:RFTX:NST?
Syntax
:FETCh:WCDMa:RFTX:NSTair:POWer?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
The query form of this command returns the latest result value of the
MEASure:WCDMa:CONT|ARRay:RFTX:NSTair:POWer measurement. The
values delivered will contain at least seven floating-point numbers in dBm.