Appendix A SCPI Command Reference
FETCh Subsystem
WCDMA Options Version 6.20
373
:FETCh:WCDMa:UEReport:CPICh:ECNO
:FETCh:WCDMa:UEReport:CPICh:RSCP
:FETCh:WCDMa:UEReport:PLOSs
Query
The query delivers a string, containing 6 measurement result values, separated by
commas started by MEASure:WCDMa[:CONT|ARRay]:UEReport:ALL. The
order and type of these measurement result values delivered is as follows:
1. CPICh ECNO, floating point real number representing UE measured normalized
chip energy per noise value of the P-CPICH,
2. CPICh RSCP, floating point real number representing UE measured received sig-
nal code power of the P-CPICH,
3. PLOSs, floating point real number representing the pathloss between Node B and
UE, estimated by the UE,
4. TXPower, floating point real number representing the UE transmit power,
5. RTTDifference, floating point real number representing UE measured RX-
Time-Difference between UL and DL signal,
6. TRCH BLER, floating point real number representing the UE estimated BLER
value for the Transport Channel defined with
CONFigure:WCDMa:MEASure:UEReport:TRCH.
Note: For a further description of the single measurements, see description of the
related commands below.
Example
:MEAS:WCDM:UER:ALL?
:FETC:WCDM:UER:ALL?
All UE Report measurements will be performed in a sequence, e.g.
23,85,102,97,992,3.
Syntax
:FETCh:WCDMa:UEReport:CPICh:ECNO?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
Reports the UE measured normalized chip energy per noise value of the P-CPICH
started by
MEASure:WCDMa[:CONT|ARRay]:UEReport:CPICh:ECNO.
Example
:FETC:WCDM:UER:CPICh:ECNO?
Starts the measurement and returns the result, e.g. 22
.
Syntax
:FETCh:WCDMa:UEReport:CPICh:RSCP?
Parameters
There are no parameters.
Description
Only the query form is supported.
Query
Reports the UE measured received signal code power of the P-CPICH started by
MEASure:WCDMa[:CONT|ARRay]:UEReport:CPICh:RSCP.
Example
:FETC:WCDM:UER:CPICh:RSCP?
Starts the measurement and returns the result, e.g. 74
.
Syntax
:FETCh:WCDMa:UEReport:PLOSs?
Parameters
There are no parameters.