5-18 Phaser 6125/6130 Color Laser Printer Service Manual
Print-Quality Troubleshooting
Perpendicularity
■ 114.5 mm ± 0.8 mm
Magnification Error
■ Horizontal Simplex: 190 mm ± 0.5%
■ Horizontal Duplex:190 mm ± 0.8%
■ Vertical Simplex: 234 mm ± 0.5%
■ Vertical Duplex: 234 mm ± 0.8%
Lead Edge
Assumed Perfect Line
Perpendicularity = B - b (within ±1.0 mm)
A
B
C
90
140 mm
F
b
s6130-208
B
J
EG
Magnification = Measured Length / Nominal (within ±0.5%)
Nominal = 280 mm
Nominal = 180 mm
s6130-209