Drive Model Figure
Dimensions mm (in)
Wt. kg
(lb)
W H D W1 W2 H0 H1 H2 H3 H4 D1 t1 t2 d
Dimensions below are the dimensions of IP00/Open Type models after customer installation of the appropriate IP20/NEMA 1, UL Type 1 Kit.
2A0250A
2
456
(17.95)
960
(37.80)
330
(12.99)
325
(12.80)
7.9
(0.31)
28
(27.76)
680
(26.77)
12
(0.49)
255
(10.04)
130
(5.12)
3.3
(0.13)
3.3
(0.13)
M10
83
(183.0)
2A0312A
456
(17.95)
960
(37.80)
330
(12.99)
325
(12.80)
7.9
(0.31)
28
(27.76)
680
(26.77)
12
(0.49)
255
(10.04)
130
(5.12)
3.3
(0.13)
3.30
(0.13)
M10
88
(194.0)
2A0360A
194
(19.84)
1168
(45.98)
35
(13.78)
370
(14.57)
7.9
(0.31)
800
(31.50)
773
(30.43)
13
(0.51)
368
(14.49)
130
(5.12)
4.6
(0.18)
4.6
(0.18)
M12
108
(238.1)
<1> Removing
the top protective cover from an IP20/NEMA 1, UL Type 1 enclosure drive voids NEMA 1, UL Type 1 protection while retaining IP20
conformity.
Table 2.3 Dimensions for IP20/NEMA 1, UL Type 1 Enclosure: 400 V Class
Drive Model Figure
Dimensions mm (in)
Wt. kg
(lb)
W H D W1 W2 H0 H1 H2 H3 H4 D1 t1 t2 d
4A0002F
1
<1>
140
(5.51)
300
(11.81)
147
(5.79)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
38
(1.50)
5
(0.20)
M5
3.4
(7.5)
4A0004F
140
(5.51)
300
(11.81)
147
(5.79)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
38
(1.50)
5
(0.20)
M5
3.4
(7.5)
4A0005F
140
(5.51)
300
(11.81)
147
(5.79)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
38
(1.50)
5
(0.20)
M5
3.4
(7.5)
4A0007F
140
(5.51)
300
(11.81)
164
(6.46)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
55
(2.17)
5
(0.20)
M5
3.6
(7.9)
4A0009F
140
(5.51)
300
(11.81)
164
(6.46)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
55
(2.17)
5
(0.20)
M5
3.8
(8.2)
4A0011F
140
(5.51)
300
(11.81)
164
(6.46)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
55
(2.17)
5
(0.20)
M5
3.8
(8.2)
4A0018F
140
(5.51)
300
(11.81)
167
(6.57)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
55
(2.17)
5
(0.20)
M5
4.0
(9.0)
4A0023F
140
(5.51)
300
(11.81)
167
(6.57)
122
(4.80)
260
(10.24)
248
(9.76)
6
(0.24)
40
(1.57)
1.5
(0.06)
55
(2.17)
5
(0.20)
M5
4.0
(9.0)
4A0031F
180
(7.09)
340
(13.39)
167
(6.57)
160
(6.30)
300
(11.81)
284
(11.18)
7.9
(0.31)
40
(1.57)
1.5
(0.06)
55
(2.17)
5
(0.20)
M5
5.8
(12.6)
4A0038F
180
(7.09)
340
(13.39)
187
(7.36)
160
(6.30)
300
(11.81)
284
(11.18)
7.9
(0.31)
40
(1.57)
1.5
(0.06)
75
(2.95)
5
(0.20)
M5
6.0
(13.2)
4A0044F
220
(8.66)
400
(15.75)
197
(7.76)
195
(7.68)
35
(13.78)
335
(13.19)
7.9
(0.31)
50
(1.97)
1.5
(0.06)
78
(3.07)
5
(0.20)
M6
8.8
(19.2)
4A0058F
2
<1>
254
(10.00)
465
(18.31)
258
(10.16)
195
(7.68)
7.9
(0.31)
400
(15.75)
385
(15.16)
7.7
(0.30)
65
(2.56)
100
(3.94)
2.2
(0.09)
2.2
(0.09)
M6
23
(50.7)
4A0072F
279
(10.98)
515
(20.28)
258
(10.16)
220
(8.66)
7.9
(0.31)
450
(17.72)
435
(17.13)
7.7
(0.30)
65
(2.56)
100
(3.94)
2.2
(0.09)
2.2
(0.09)
M6
27
(59.5)
4A0088F
329
(12.95)
630
(24.80)
258
(10.16)
260
(10.24)
7.9
(0.31)
509
(20.08)
495
(19.49)
7.7
(0.30)
120
(4.72)
105
(4.13)
2.2
(0.09)
3.3
(0.13)
M6
39
(86.0)
4A0103F
329
(12.95)
630
(24.80)
258
(10.16)
260
(10.24)
7.9
(0.31)
509
(20.08)
495
(19.49)
7.7
(0.30)
120
(4.72)
105
(4.13)
2.2
(0.09)
3.3
(0.13)
M6
39
(86.0)
4A0139F
329
(12.95)
730
(28.74)
283
(11.14)
260
(10.24)
7.9
(0.31)
550
(21.65)
535
(21.06)
7.7
(0.30)
180
(7.09)
110
(4.33)
2.2
(0.09)
2.2
(0.09)
M6
45
(99.2)
4A0165F
329
(12.95)
730
(28.74)
283
(11.14)
260
(10.24)
7.9
(0.31)
550
(21.65)
535
(21.06)
7.7
(0.30)
180
(7.09)
110
(4.33)
2.2
(0.09)
2.2
(0.09)
M6
46
(101.4)
Dimensions below are the dimensions of IP00/Open Type models after customer installation of the appropriate IP20/NEMA 1, UL Type 1 Kit.
4A0208A
2
456
(17.95)
960
(37.80)
330
(12.99)
325
(12.80)
7.9
(0.31)
28
(27.76)
680
(26.77)
12
(0.49)
255
(10.04)
130
(5.12)
3.3
(0.13)
3.3
(0.13)
M10
87
(191.8)
4A0250A
194
(19.84)
1168
(45.98)
35
(13.78)
370
(14.57)
7.9
(0.31)
800
(31.50)
773
(30.43)
13
(0.51)
368
(14.49)
130
(5.12)
4.6
(0.18)
4.6
(0.18)
M12
106
(233.7)
4A0296A
194
(19.84)
1168
(45.98)
35
(13.78)
370
(14.57)
7.9
(0.31)
800
(31.50)
773
(30.43)
13
(0.51)
368
(14.49)
130
(5.12)
4.6
(0.18)
4.6
(0.18)
M12
112
(246.9)
4A0362A
194
(19.84)
1168
(45.98)
35
(13.78)
370
(14.57)
7.9
(0.31)
800
(31.50)
773
(30.43)
13
(0.51)
368
(14.49)
130
(5.12)
4.6
(0.18)
4.6
(0.18)
M12
117
(257.9)
<1> Removing
the top protective cover from an IP20/NEMA 1, UL Type 1 enclosure drive voids NEMA 1, UL Type 1 protection while retaining IP20
conformity.
2.1 Mechanical Installation
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
33
2
Mechanical Installation

Table of Contents

Other manuals for YASKAWA A1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA A1000 Series and is the answer not in the manual?

YASKAWA A1000 Series Specifications

General IconGeneral
SeriesA1000
TypeAC Drive
AltitudeUp to 1000m without derating
Output Frequency0-400 Hz
Control MethodV/f Control
Overload Capacity150% for 60 seconds
Communication OptionsModbus, DeviceNet, Profibus, Ethernet/IP
Ambient Temperature-10 to 50°C
Storage Temperature-20 to 60°C
Humidity5% to 95% (non-condensing)
Enclosure RatingIP20
Horsepower0.5 to 1000 HP
Power Range0.4 - 630 kW (varies by voltage and model)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Cooling MethodFan Cooled
SafetySafe Torque Off (STO)