YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 133
Drive Model
The maximum applicable motor
output
kW (HP)
Input Current Rating
A
Semiconductor Protection Fuse
Rated Current
Manufacturer: EATON/Bussmann
4005 1.5 (2) 4.7 FWH-50B
4006 2.2 (3) 6.7 FWH-60B
4007 3 (4) 8.9 FWH-60B
4009 4.0 (5.3) 11.7 FWH-60B
4015 5.5 (7.5) 15.8 FWH-80B
4018 7.5 (10) 21.2 FWH-90B
4024 11 (15) 30.6 FWH-150B
4031 15 (20) 41.3 FWH-200B
4039 18.5 (25) 50.5 FWH-200B
4045 22 (30) 43.1 FWH-225A
4060 30 (40) 58.3 FWH-250A
4075 37 (50) 71.5 FWH-275A
4091 45 (60) 86.5 FWH-275A
4112 55 (75) 105 FWH-300A
4150 75 (100) 142
FWH-325A
FWH-400A
*1
4180 90 (125) 170 FWH-500A
4216 110 (150) 207 FWH-600A
4260 132 (175) 248 FWH-700A
4304
*2
160 (200) 300 FWH-800A
4371
*2
200 (250) 373 FWH-1000B
4414
*2
220 (300) 410 FWH-1200B
4453
*2
250 (335) 465 FWH-1200B
4605
*2
315 (400) 584
FWH-1400A
FWH-1600A
*1
*1 Yaskawa recommends a fuse with a large rated current for applications with repeated loads.
*2 Approval pending. Contact Yaskawa or your nearest sales representative.