Startup Procedure and Test Run
3
3.10 Crane Application Setup Procedure
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 219
Item Parameter Name
Motor Switch Command
Motor 1 Motor 2 Motor 3
Brake Sequence
Brake Sequence Selection
*1
S1-54 S1-55 S1-56
Brake Release Frequency(FWD) S1-01 S1-23 S1-52
Brake Release Frequency(REV) S1-02 S1-24 S1-52
Brake Delay Frequency S1-03 S1-25 -
Brake Delay Time S1-04 S1-26 0.00 s
Brake Release Current (FWD) S1-05 S1-27 0%
Brake Release Current (REV) S1-06 S1-28 0%
Brake Release Torque (FWD) S1-07 S1-29 -
Brake Release Torque (REV) S1-08 S1-30 -
Torque Compensation (FWD) S1-09 S1-31 -
Torque Compensation (REV) S1-10 S1-32 -
Torque Compensation Delay Time S1-11 S1-33 -
Brake Hold Frequency (FWD) S1-12 S1-34 S1-53
Brake Hold Frequency (REV) S1-13 S1-35 S1-53
Slip Prevention Frequency S1-14 S1-36 -
Slip Prevention Time S1-15 S1-37 0.00 s
Sequence Fault SE1 Detect Time S1-16 S1-38 0.00 s
Sequence Fault SE2 Detect Time S1-17 S1-39 0.00 s
Sequence Fault SE3 Detect Time S1-18 S1-40 0.00 s
Sequence Fault SE4 Detect Time S1-19 S1-41 0.00 s
Operation in Reverse S1-20 S1-42 -
*1 Set S1-54 to S1-56 = 0 [Disabled] when you do not use the brake sequence.
Note:
• When the 3 motors are used, a protective function set in L1-01 [Motor Overload (oL1) Protection] is applied to motor 1 and motor 2
only. For motor 3, set up a thermal overload relay between the drive and motor 3, so that the sequence trips an external fault (coast to
stop).
• You cannot switch between V/f patterns during run for motor 3. Even when b1-23 = 1 [Selection REV Parameters = Enabled], the
drive will not switch between motors even when the counterweight signal is input.
• If the frequency reference exceeds the maximum output frequency, then it will still be limited by the maximum output frequency set to
each motor. For example, if you set E1-04 = 60 Hz, E3-04 = 50 Hz, d1-04 [Reference 4] = 60 Hz, and d1-04 as the part of multi-step
speed reference, then the frequency reference for motor 1 will be 60 Hz, and 50 Hz for motor 2.
• Refer to the following for the default settings change as the control method.
–
–
Table 3.23 Multi-Funciton Digital Input
H1-xx
Setting Value
Name Description
16 Motor 2 Selection Switches between motors 1 and 2.
ON: Selects motor 2
OFF: Selects motor 1
39 Motor 3 Selection Switches to motor 3. It is necessary to set H1-xx = 16 when setting H1-xx = 39. If H1-xx = 39 is
set while H1-xx = 16 is not set, oPE03 [Multi-Function Input Setting Err] is detected.
ON: Selects motor 3
OFF: Clears the selection of motor 3
Note:
When H1-xx = 16 and/or 39, the drive does not detect oPE08 [Parameter Selection Error] concerning contradictory settings in the
MFDIs, MFDOs, analog inputs, and monitor outputs. The drive recognizes terminals that have not been set to a function as "Not Used".