Network Communications
5
5.3 MEMOBUS/Modbus Communications
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 315
Register No.
(Hex.)
Description
3006
Date Setting
Setting range: 101 to 1231 (decimal), the default value at power up: 101
Set the month and the date in MMDD format.
MM: 01 to 12 (decimal)
DD: 01 to 31 (decimal)
3007
Set the Date Information
Setting range: 0 to 8 (decimal), the default value at power up: 8
Set the values specified in 3004H to 3006H as the date and time.
Command Data: 1
Response Data: 0 (normal), 8 (fault)
Monitor Data
Monitor data can only be read.