10.8 E: Motor Parameters
486 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
No.
(Hex.)
Name Description
Default
(Range)
Ref.
E7-12
(1B69)
Expert
Motor 3 Mid Point B
Voltage
Sets the mid point B voltage used for motor 3.
Note:
Usually it is not necessary to change this parameter. Set this parameter to adjust the
V/f pattern for the constant output range.
0.0 V
(200 V Class: 0.0 to
255.0 V, 400 V Class:
0.0 to 510.0 V)
650
E7-13
(1B6A)
Expert
Motor 3 Base Voltage
Sets the base voltage used for motor 3.
Note:
Usually it is not necessary to change this parameter. Set this parameter to adjust the
V/f pattern for the constant output range.
0.0 V
(200 V Class: 0.0 to
255.0 V, 400 V Class:
0.0 to 510.0 V)
650
E7-21
(1B72)
Motor 3 Rated Current
Sets the motor rated current for motor 3 in amperes.
Determined by o2-04
(10% to 200% of the
drive rated current)
650
E7-24
(1B75)
Motor 3 Motor Poles
Sets the number of poles for motor 3.
4
(2 - 48)
650
E7-25
(1B76)
Motor 3 Line-to-Line
Resistance
Sets the line-to-line resistance for the motor 3 stator windings.
Determined by o2-04
(0.000 - 65.000 Ω)
650
E7-31
(1B7C)
Motor 3 Rated Power
Sets the motor 3 rated power in 0.01 kW. (1 HP = 0.746 kW) (1 HP = 0.746 kW)
Determined by o2-04
(0.00 - 650.00 kW)
650