10.16 U: Monitors
550 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
No.
(Hex.)
Name Description MFAO Signal Level
U6-88 to U6-91
(07B8, 07B9,
07F0, 07F1)
Online Gateways 1 to 4
Shows the currently available gateway address.
U6-88: 1st octet
U6-89: 2nd octet
U6-90: 3rd octet
U6-91: 4th octet
No signal output available
U6-92
(07F2)
Online Speed
Shows the currently available communications speed.
10: 10 Mbps
100: 100 Mbps
No signal output available
U6-93
(07F3)
Online Duplex
Shows the currently available Duplex setting.
No signal output available
U6-98
(07F8)
First Fault
Shows the contents of the most recent communication options fault (DeviceNet, Modbus TCP/IP,
EtherNet/IP).
No signal output available
U6-99
(07F9)
Current Fault
Shows the contents of current fault from communication options (DeviceNet, Modbus TCP/IP,
EtherNet/IP).
No signal output available
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV

Table of Contents

Other manuals for YASKAWA CR700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA CR700 and is the answer not in the manual?

YASKAWA CR700 Specifications

General IconGeneral
BrandYASKAWA
ModelCR700
CategoryDC Drives
LanguageEnglish

Related product manuals