Parameter List
10
10.17 Parameters that Change from the Default Settings with A1-02 [Control Method Selection]
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 553
No. Name Range Unit
Control Method (A1-02 Setting)
V/f
(0)
CL-V/f
(1)
OLV
(2)
CLV
(3)
AOLV
(4)
n1-15
PWM Voltage
Offset
Calibration
0 - 2 1 1 1 1 1 2
o1-03
Frequency
Display Unit
Selection
0 - 3 1 0 0 0 0 0
o1-04
V/f Pattern
Display Unit
0 - 1 1 - - - 0 0
S1-03
Brake Delay
Frequency
0.0 - 400.0  0.1 Hz 3.0 3.0 3.0 0.0 3.0
S1-04
Brake Delay
Time
0.00 - 10.00 0.01 s 0.30 0.30 0.30 0.00 0.30
S1-09
Torque
Compensation
(FWD)
-200 - +200 1% - - 50 0 50
S1-14
Slip Prevention
Frequency
0.0 - 20.0 0.1 Hz 3.0 3.0 3.0 0.0 3.0
S1-15
Slip Prevention
Time
0.00 - 10.00 0.01 s 0.30 0.30 0.30 0.00 0.30
S3-01
Impact Stop
Creep Frequency
0.0 - 20.0 0.1 Hz 6.0 6.0 3.0 3.0 3.0
*1 The default setting changes when the drive model and E1-03 [V/f Pattern Selection] change.