Parameter Details
11
11.2 A: Initialization Parameters
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 575
No. Name Optimal Value
d1-02 Reference 2 25.00 Hz
d1-03 Reference 3 50.00 Hz
H1-05 Terminal S5 Function Selection 3: Multi-Step Speed Reference 1
H1-06 Terminal S6 Function Selection 4: Multi-Step Speed Reference 2
H2-01 Term M1-M2 Function Selection 0: During Run
H2-02 Term M3-M4 Function Selection 37: During Frequency Output
H3-06 Terminal A3 Function Selection F: Not Used (Through Mode)
L3-04 Stall Prevention during Decel 0: Disabled
L8-05 Input Phase Loss Protection Sel 1: Enabled
L8-07 Output Phase Loss Protection Sel 1: Fault when One Phase is Lost
L8-38 Carrier Frequency Reduction 1: Enabled below 6 Hz
L8-41 High Current Alarm Selection 1: Enabled
S1-01 Brake Release Frequency (FWD) 0.0 Hz
S1-02 Brake Release Frequency (REV) 0.0 Hz
S1-03 Brake Delay Frequency 0.0 Hz
S1-04 Brake Delay Time 0.00 s
S1-12 Brake Hold Frequency (FWD) 0.0 Hz
S1-13 Brake Hold Frequency (REV) 0.0 Hz
S1-14 Slip Prevention Frequency 0.0 Hz
S1-15 Slip Prevention Time 0.00 s
S1-16 Sequence Fault SE1 Detect Time 0.00 s
S1-17 Sequence Fault SE2 Detect Time 0.00 s
S1-18 Sequence Fault SE3 Detect Time 0.00 s
S1-19 Sequence Fault SE4 Detect Time 0.00 s
S1-54 Brake Sequence Selection 0: Disabled
The drive saves these parameters as user parameters.
Table 11.5 Parameters Saved as User Parameters with the Traveling Preset
User Parameter No. Parameter No. Saved Name
A2-01 b1-01 Frequency Reference Selection 1
A2-02 C1-01 Acceleration Time 1
A2-03 C1-02 Deceleration Time 1
A2-04 d1-01 Reference 1
A2-05 d1-02 Reference 2
A2-06 d1-03 Reference 3
A2-07 E2-01 Motor Rated Current (FLA)
A2-08 H1-05 Terminal S5 Function Selection
A2-09 H1-06 Terminal S6 Function Selection
A2-10 H2-01 Term M1-M2 Function Selection
A2-11 L1-01 Motor Overload (oL1) Protection
3 : Closed Loop Crane (Hoist)
The drive automatically sets these parameters for a closed loop crane (hoist) application.
Table 11.6 Optimal Settings for Closed Loop Crane (Hoist) Applications
No. Name Optimal Value
A1-02 Control Method Selection 3: Closed Loop Vector (CLV)
b1-01 Frequency Reference Selection 1 0: Keypad