EasyManua.ls Logo

YASKAWA CR700

YASKAWA CR700
886 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.9 Change the Drive Enclosure Type
60 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
Note:
The number of screws are different for different models.
100-192-121-007: 4 screws
100-192-121-008: 6 screws
A - M4 × 8 pan head screws B - Base
Figure 2.54 Install the Base on the Stay Brackets
3. Use the included bolts to install the UL Type 1 base to the drive.
Tighten the bolts to a correct tightening torque:
M6 × 16 upset bolts 3.92 Nm to 4.90 Nm (34.70 lbfin to 43.37 lbfin)
M8 × 16 hex bolts: 8.83 Nm to 10.79 Nm (78.15 lbfin to 95.49 lbfin)
A - M6 × 16 upset head bolts
B - M8 × 16 hex bolts
C - M8 plain washers
D - Base
Figure 2.55 Safety the Base
4. Use the included screws to install the UL Type 1 conduit bracket to the base.
Tighten the screws to a correct tightening torque:
0.98 Nm to 1.33 Nm (8.67 lbfin to 11.77 lbfin)