◆ Multi-Function Analog Inputs (H3-02/H3-06/H3-10) 
H3 Multi-Function Analog Inputs 
Setting 
Value 
Function 
Description  Ref.
28  Wire Length 
V/f      CL-V/f     OLV      CLV     AOLV 
Inputs the wire length to the drive as analog input. This input is used when S9-14 =
1. 
100% = S9-19 [Wire Length] 
0% = S9-20 [Wire Length@Rolling Up]
 
10
 
◆ 
MEMOBUS Inputs 
MEMOBUS Inputs 
Register 
No. 
(Hex.) 
Function  Range  Resolution  Unit  Description  Ref.
00F4 
Wire 
Length 
0.0 to 
100.0 
0.1  % 
V/f      CL-V/f     OLV      CLV     AOLV 
Inputs the wire length to the drive as analog input. This input is 
used when S9-14 = 2. 
100% = S9-19 [Wire Length] 
0% = S9-20 [Wire Length@Rolling Up]
 
10
 
◆ 
Monitors 
No. 
(Hex.) 
Name  Description  MFAO Signal Level  Unit  Ref.
U9: Dedicated Application Monitors 
U9-01 
(0820) 
Expert 
Hook Position 
(NumR) 
V/f
 
    CL-V/f      OLV      CLV     AOLV 
Displays the current position of the hook as the 
number of motor rotations. The number of motor 
rotations is always the Forward Limit Position 
(forward travel limit = 0 revolutions). 
 
No signal output 
available 
1 
rotation
5 
U9-02 
(0821) 
Expert 
Hook Position 
(%) 
V/f
 
    CL-V/f      OLV      CLV     AOLV 
Displays the current position of the hook (U9-01) as 
a percentage. 
The reference position is set with S9-05. The display 
is limited between 0% and 100%. 
 
10 V: Hook 
RangeLim Number 
of Rotation 
0.1%  5 
U9-06 
(0825) 
Expert 
Wire Length 
V/f      CL-V/f     OLV      CLV     AOLV 
The monitor value of the wire length. 
The wire length after wire length correction is 
output.
 
10 V: Wire Length 
(S9-19) 
0.1 m  14