EZZ023535 
14 / 35 
  SA-47 Slave Dev Sel 
No.   
(Hex.) 
Name  Description 
Default Setting 
(Range) 
SA-47   
(1AC9) 
Slave Dev Sel 
 
Selects the slave drive operation when position deviation 
exceeds the setting value of SA-46. 
2   
(0 - 2) 
0: No Detection 
The drive continues operation. 
1: Alarm Only 
The FdEv alarm is displayed, but the drive continues operation. 
2: Coast to Stop 
The FdEv alarm is displayed, and the motor coasts to stop. 
 
 
SA-48 MOP Mem @Pwr Off 
No.   
(Hex.) 
Name  Description 
Default Setting 
(Range) 
SA-48   
(1ACA) 
MOP Mem @Pwr Off 
 
Selects the handling of the MOP adjustment value when 
the power supply is turned OFF. 
0   
(0, 1) 
0: Disabled 
Resets the MOP adjustment value when the power supply is turned OFF. 
1: Enabled 
Retains the MOP adjustment value even after the power supply is turned OFF. 
 
 
SA-51 Position P Gain 
No.   
(Hex.) 
Name  Description 
Default Setting 
(Range) 
SA-51   
(1ACB)   
RUN 
Position P Gain 
 
Sets proportional gain for the position controller. Position P 
Gain (SA-51) is set based on Maximum Output Frequency 
(E1-04) of the drive. 
Note: Enabled only when set to Position Synchronization 
mode. 
Note: When the setting of E1-04 is changed, position 
controller output will be affected. 
5.00   
(0.00 - 100.00) 
 
 
SA-52 Position I Time 
No.   
(Hex.) 
Name  Description 
Default Setting 
(Range) 
SA-52   
(1ACC)   
RUN 
Position I Time 
 
Sets integral time for the position controller. 
Note: Enabled only when set to Position Synchronization 
mode. 
0.00 s   
(0.00 - 50.00 s) 
 
 
SA-53 Pos Filter Time 
No.   
(Hex.) 
Name  Description 
Default Setting 
(Range) 
SA-53   
(1ACD)   
RUN 
Pos Filter Time 
 
 
Sets the filter time for position controller output. 
Note: Enabled only when set to Position Synchronization 
mode. 
0.00 s   
(0.00 - 1.50 s)