Refitting the battery pack
Use these procedures to refit the battery pack.
Refitting the battery pack
NoteAction
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section WARNING - The unit is sensitive to ESD!
on page 55
1
xx1500000506
Fit the battery and and secure it with a cable tie.
Note
Battery includes protection circuits. Only replace
with a specified spare part or with an ABB-ap-
proved equivalent.
2
xx1500000505
Connect the battery connector (X3).3
Tightening torque: 0.9 Nm.
xx1500000697
Refit the body cover.4
Continues on next page
124 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
3 Maintenance
3.4.1 Replacing the battery pack
Continued