Removing the expansion board complete
NoteAction
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section WARNING - The unit is sensitive to ESD!
on page 55
2
A
xx1300000859
Attachment screw (2 pcs)A
Remove the attachment screws on the computer
unit.
3
Grip the expansion board and gently pull it straight
out.
CAUTION
Always grip the expansion board around the
edges to avoid damage to the board or its com-
ponents.
4
Refitting the expansion board complete
Use this procedure to refit the expansion board complete.
Refitting the expansion board complete
NoteAction
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
Continues on next page
Product manual - IRB 14000 385
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.14 Replacing the expansion board complete
Continued