Removing the motor
Use these procedures to remove the axis-3 motor.
Preparations before removing the motor
NoteAction
The figure shows the specified position on
the left arm:
xx1500000586
Jog the robot to the specified position:
Axis 1, axis 7 and axis 2: brake re-
lease and rotate so that axis-3 motor
shaft is vertical.
Axis 3: rotate in positive direction
until the axis is secured against the
axis-3 mechanical stop.
Axis 4: No significance.
Axis 5: No significance.
Axis 6: No significance.
1
DANGER
Turn off all:
electric power supply
air pressure supply
to the robot, before starting the repair work
on the robot.
2
xx1400002751
Remove the lower axis-3 cover.3
Removing the axis-3 motor
NoteAction
DANGER
Make sure that all supplies for electrical
power and air pressure are turned off.
1
Continues on next page