2.4.2 Connecting power and the FlexPendant
Overview
The following illustration shows the connectors on the right side of the controller.
xx1500000503
Power switchQ1
FlexPendantXS4
Power inputXP0
Main AC power connector, IEC 60320-1 C14, 100-240 VAC, 50-60 Hz
Connecting power supply
Line fusing
Line fusing of the IRB 14000 is 5A at 100-240 V.
Rated power
Rated power of the IRB 14000 is 360 W.
Required equipment
NoteEquipment
Power supply cable (single phase)
8AExternal circuit breaker
30mAExternal earth fault protection at control cables 3 -15m
300mAExternal earth fault protection at control cables >15m
See Circuit diagram - IRB 14000.Circuit diagram
Continues on next page
90 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
2 Installation and commissioning
2.4.2 Connecting power and the FlexPendant