Removing the capacitor bank
Use this procedure to remove the capacitor bank.
Pulling the controller out partially
NoteAction
DANGER
Turn off all:
electric power supply
air pressure supply
to the robot, before starting the repair work on the
robot.
1
Flange screw (10 pcs)
xx1500000525
Remove the body cover.
ELECTROSTATIC DISCHARGE (ESD)
The equipment is sensitive to ESD. Before hand-
ling the equipment please read the safety inform-
ation in the section WARNING - The unit is sens-
itive to ESD! on page 55
2
xx1500000303
xx1500000364
Remove the attachment screws that fasten the
controller to the body.
3
Put a trolley beneath the controller.4
Continues on next page