Removing the motor
Use these procedures to remove the axis-2 motor.
Preparations before removing the motor
NoteAction
Figure shows position of left arm:
xx1500000585
Jog the robot to the specified position:
Right arm:
Axis 1: 42°
Axis 2: rotate in positive direction
until the axis is secured against the
axis-2 mechanical stop.
Axis 7: brake release to position the
axis hanging straight down.
Axis 3: brake release to position the
axis hanging straight down.
Axis 4: No significance.
Axis 5: No significance.
Axis 6: No significance.
Left arm:
Axis 1: 120°
Axis 2: rotate in positive direction
until the axis is secured against the
axis-2 mechanical stop.
Axis 7: brake release to position the
axis hanging straight down.
Axis 3: brake release to position the
axis hanging straight down.
Axis 4: No significance.
Axis 5: No significance.
Axis 6: No significance.
1
DANGER
Turn off all:
electric power supply
air pressure supply
to the robot, before starting the repair work
on the robot.
2
Removing the body covers
NoteAction
DANGER
Make sure that all supplies for electrical
power and air pressure are turned off.
1
Continues on next page
152 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.4.2 Replacing the axis-2 motor
Continued