EasyManua.ls Logo

ABB IRB 14000 - Page 384

ABB IRB 14000
458 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
A
xx1500001755
Grip the loosened attachment screws and gently
pull the fieldbus adapter straight out.
5
Opening the computer
NoteAction
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section WARNING - The unit is sensitive to ESD!
on page 55
2
(Depending on which connection is installed)3
Disconnect the connector:
Profibus/S: A32.2
Ethernet/IP/S: A32.1
ProfiNet/S: A32.3
B
A
xx1300000684
Attachment screw (4 pcs)A
CoverB
Open the computer unit by removing the attach-
ment screws and lift the cover off.
CAUTION
Be careful not to stretch the fan cable.
4
Disconnect the fan connector.5
Continues on next page
384 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.14 Replacing the expansion board complete
Continued