Refitting the mass memory card
Refitting the mass memory card
NoteAction
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section WARNING - The unit is sensitive to ESD!
on page 55
2
CAUTION
Make sure that the memory card is oriented cor-
rectly before inserting it. Otherwise the memory
card or the memory slot may be damaged.
3
Mass memory with boot loader:
3HAC047184-003
Gently push the memory card with the finger until
it clicks into place.
4
Refitting the fan
NoteAction
Connect the fan connector.
E1.XS1
1
Screws: M3x6 8.8-A2F (4 pcs).Refit the bottom cover and tighten the screws.
CAUTION
Be careful not to damage the cables.
2
Tightening torque: 0.2 Nm
xx1500000310
378 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.13 Replacing the mass memory card
Continued