DeltaChill™ Air Cooled and FreeCool
208
Chiller Technical Manual 7267818 V1.13.0_01_2018
Air Cooled
ELECTRICAL DATA 164 165 166
Unit Data DCC075TX-15GYYY DCC077TX-16GYYV DCC072TX-17GPYY
Nominal Run Amps (1) A 511.7 539.7 493.3
Maximum Start Amps A 787.3 807.1 756.7
Recommended Mains Fuse Size A 560 560 560
Evaporator
Immersion Heater Rating W 250 250 250
Condenser Fan - Per Fan (EC)
Quantity 15 16 17
Full Load Amps A 3.9 3.9 3.9
Motor Rating kW 2.6 2.6 2.6
Compressor - Per Compressor
Nominal Run Amps A 47.9 / 47.9 / 47.9 47.9 / 47.9 / 55.2 59.2 / 47.9 / 47.9
Quantity 3 + 3 + 3 3 + 3 + 3 2 + 3 + 3
Motor Rating kW 29.8 / 29.8 / 29.8 29.8 / 29.8 / 33.1 36.2 / 29.8 / 29.8
Sump Heater Rating W 140 140 140
Start Amps (2) A 326 / 326 / 326 326 / 326 / 326 298 / 326 / 326
OPTIONAL EXTRAS
Power Factor Correction (PF 0.98) (3)
Nominal Run Amps A 489.1 510.3 469.7
Reactive power reduction/saving (4) kVAr 42.8 54.0 44.2
Maximum Start Amps A 764.7 777.7 733.1
Recommended Mains Fuse Size A 560 560 560
Electronic Soft-start
Nominal Run Amps A 511.7 539.7 493.3
Maximum Start Amps A 656.9 676.7 626.3
Recommended Mains Fuse A 560 560 560
Power Factor Correction (PF
0.98) & Electronic Soft Start (3)
Nominal Run Amps A 489.1 510.3 469.7
Maximum Start Amps A 634.3 647.3 602.7
Recommended Mains Fuse Size A 560 560 560
Standard Head Pump (Single
or Run/Standby)
Pump Full Load Amps A 11.2 11.2 11.2
Unit Nominal Run Amps A 522.7 550.7 504.3
Recommended Mains Fuse Size A 560 630 560
Motor Rating kW 6.2 6.2 6.2
Larger Head Pump (Single
or Run/Standby)
Pump Full Load Amps A 21.2 21.2 21.2
Unit Nominal Run Amps A 532.6 560.7 514.3
Recommended Mains Fuse Size A 560 630 560
Motor Rating kW 12.1 12.1 12.1
Standard Head Inverter Pump
(Single or Run/Standby)
Pump Full Load Amps A 10.2 10.2 10.2
Unit Nominal Run Amps A 520.1 548.0 501.6
Recommended Mains Fuse Size A 560 630 560
Motor Rating kW 6.4 6.4 6.4
Larger Head Inverter Pump
(Single or Run/Standby)
Pump Full Load Amps A 19.8 19.8 19.8
Unit Nominal Run Amps A 528.0 555.8 509.5
Recommended Mains Fuse Size A 560 630 560
Motor Rating kW 12.4 12.4 12.4
(1) Based at 7.2°C Evap / 54.4°C Condensing, AC Standard Fans.
(2) Starting amps refers to the direct on line connections.
(3) For unit RLA values at alternative power factor values contact Airedale.
(4) Projected reactive power reduction based on a 0.95PF billing threshold
DCC Electrical Data - Extra Quiet