Example usage:
To display all method lists for promoting user level privileges to administrator level privileges:
AT-9724TS:4# show authen_enable all
Command: show authen_enable all
Method List Name P r i o r i t y Method Name C o m m e n t
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
P e r m i t 1 t a c a c s + Built-in Group
2 t a c a c s Built-in Group
3 D a r r e n User-defined Group
4 l o c a l K e y w o r d
d e f a u l t 1 t a c a c s + Built-in Group
2 l o c a l K e y w o r d
Total Entries: 2
A T - 9 7 2 4 T S : 4 #
config authen application
Purpose Used to configure various applications on the Switch for authentication using a previously configured method
list.
Syntax config authen application [console | telnet | ssh | http | all] [login|enable][default|method
list name<string15>][login | enable] [default | method_list_name <string 15>]
Description This command is used to configure switch configuration applications (console, telnet, ssh, web) for login at the
user level and at the administration level (authen_enable) utilizing a previously configured method list.
Parameters application – Choose the application to configure.The user may choose one of the following four applications to
configure:
console – Choose this parameter to configure the command line interface login method.
telnet – Choose this parameter to configure the telnet login method.
ssh - Choose this parameter to configure the SSH (Secure Shell) login method.
http – Choose this parameter to configure the web interface login method.
all – Choose this parameter to configure all applications (console, telnet, web, ssh) login method.
login – Use this parameter to configure an application for normal login on the user level, using a previously
configured method list.
enable – Use this parameter to configure an application for upgrading a normal user level to administrator
privileges, using a previously configured method list.
default – Use this parameter to configure an application for user authentication using the default method list.
method_list_name <string 15> -– Use this parameter to configure an application for user authentication using a
previously configured method list. Enter a alphanumeric string of up to 15 characters to define a previously
configured method list.
Restrictions Only administrator-level users can issue this command.
Example usage:
To configure the default method list for the web interface:
AT-9724TS:4# config authen application http login default
Command: config authen application http login default
S u c c e s s .
A T - 9 7 2 4 T S : 4 #
145
Allied Telesyn AT-9724TS High-Density Layer 3 Stackable Gigabit Ethernet Switch • Command Line Interface Reference Manual

Table of Contents

Other manuals for Allied Telesis AT-9724TS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-9724TS and is the answer not in the manual?

Allied Telesis AT-9724TS Specifications

General IconGeneral
MAC address table16000 entries
Packet buffer memory2 MB
Maximum data transfer rate88 Gbit/s
Full duplexYes
Dimensions (WxDxH)440 x 210 x 44 mm
Power requirements100-240V AC/50-60Hz
Management platformSNMP, RMON
Networking featuresIEEE 802.3 10T Ethernet, IEEE 802.3u 100TX Ethernet, IEEE 802.3ab 1000T Ethernet, IEEE 802.3z 1000X Ethernet
Connectivity technologyWired
DHCP featuresDHCP client
Security algorithmsSSH
Switch typeManaged
Switch layerL3+
SFP/SFP+ slots quantity4
Basic switching RJ-45 Ethernet ports quantity24
Memory typeSDRAM / Flash
Flash memory16 MB
Internal memory256 MB
Power consumption (typical)90 W
CertificationUL 1950 FCC Class A CSA 22.2 No. 950 EN55022 Class A EN 60950 (TUV) EN50082-1 CE
Storage temperature (T-T)-25 - 55 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight3200 g