Example usage:
To configure the response timeout to never time out:
AT-9724TS:4# config authen parameter response_timeout 0
Command: config authen parameter response_timeout 0
S u c c e s s .
A T - 9 7 2 4 T S : 4 #
config authen parameter attempt
Purpose Used to configure the maximum number of times the Switch will accept authentication attempts.
Syntax config authen parameter attempt <int 1-255>
Description This command will configure the maximum number of times the Switch will accept authentication attempts.
Users failing to be authenticated after the set amount of attempts will be denied access to the Switch and will
be locked out of further authentication attempts. Command line interface users will have to wait 60 seconds
before another authentication attempt.Telnet users will be disconnected from the Switch.
Parameters parameter attempt <int 1-255> – Set the maximum number of attempts the user may try to become
authenticated by the Switch, before being locked out.The default setting is 3 attempts.
Restrictions Only administrator-level users can issue this command.
Example usage:
To set the maximum number of authentication attempts at 5:
AT-9724TS:4# config authen parameter attempt 5
Command: config authen parameter attempt 5
S u c c e s s .
A T - 9 7 2 4 T S : 4 #
show authen parameter
Purpose Used to display the authentication parameters currently configured on the Switch.
Syntax show authen parameter
Description This command will display the authentication parameters currently configured on the Switch, including the
response timeout and user authentication attempts.
This command will display the following fields:
Response timeout – The configured time allotted for the Switch to wait for a response of authentication from
the user attempting to log in from the command line interface or telnet interface.
User attempts – The maximum number of attempts the user may try to become authenticated by the Switch,
before being locked out.
Parameters None.
Restrictions None.
Example usage:
To show authentication parameters:
AT-9724TS:4# show authen parameter
Command: show authen parameter
Response timeout: 60 seconds
User attempts: 5
A T - 9 7 2 4 T S : 4 #
152
Allied Telesyn AT-9724TS High-Density Layer 3 Stackable Gigabit Ethernet Switch • Command Line Interface Reference Manual

Table of Contents

Other manuals for Allied Telesis AT-9724TS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-9724TS and is the answer not in the manual?

Allied Telesis AT-9724TS Specifications

General IconGeneral
MAC address table16000 entries
Packet buffer memory2 MB
Maximum data transfer rate88 Gbit/s
Full duplexYes
Dimensions (WxDxH)440 x 210 x 44 mm
Power requirements100-240V AC/50-60Hz
Management platformSNMP, RMON
Networking featuresIEEE 802.3 10T Ethernet, IEEE 802.3u 100TX Ethernet, IEEE 802.3ab 1000T Ethernet, IEEE 802.3z 1000X Ethernet
Connectivity technologyWired
DHCP featuresDHCP client
Security algorithmsSSH
Switch typeManaged
Switch layerL3+
SFP/SFP+ slots quantity4
Basic switching RJ-45 Ethernet ports quantity24
Memory typeSDRAM / Flash
Flash memory16 MB
Internal memory256 MB
Power consumption (typical)90 W
CertificationUL 1950 FCC Class A CSA 22.2 No. 950 EN55022 Class A EN 60950 (TUV) EN50082-1 CE
Storage temperature (T-T)-25 - 55 °C
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight3200 g