Chapter 7 - Network Management (SNMP) Commands
The network management commands in the Command Line Interface (CLI) are listed (along with the appropriate parameters) in the following table.
The AT-9724TS supports the Simple Network Management Protocol (SNMP) versions 1, 2c, and 3.You can specify which version of the SNMP you want to use to
monitor and control the Switch.The three versions of SNMP vary in the level of security provided between the management station and the network device.The
following table lists the security features of the three SNMP versions:
SNMP Version Authentication Method Description
v1 Community String Community String is used for authentication – NoAuthNoPriv
v2c Community String Community String is used for authentication – NoAuthNoPriv
v3 Username Username is used for authentication – NoAuthNoPriv
v3 MD5 or SHA Authentication is based on the HMAC-MD5 or HMAC-SHA
algorithms – AuthNoPriv
v3 MD5 DES or SHA DES Authentication is based on the HMAC-MD5 or HMAC-SHA
algorithms – AuthPriv.
DES 56-bit encryption is added based on the CBC-DES (DES-56)
standard
Each command is listed, in detail, in the following sections.
Command Parameters
create snmp user create snmp user <SNMP_name 32> <groupname 32> {encrypted [by_password auth [md5 <auth_password
8-16> | sha <auth_password 8-20>] priv [none | des <priv_password 8-16>] | by_key auth [md5 <auth_key
32-32> | sha <auth_key 40-40>] priv [none | des <priv_key 32-32>]]}
delete snmp user <SNMP_name 32>
show snmp user
create snmp view <view_name 32> <oid> view_type [included | excluded]
delete snmp view <view_name 32> [all | oid]
show snmp view <view_name 32>
create snmp community <community_string 32> view <view_name 32> [read_only | read_write]
delete snmp community <community_string 32>
show snmp community <community_string 32>
config snmp engineID <snmp_engineID>
show snmp engineID
create snmp group <groupname 32> {v1 | v2c |v3 [noauth_nopriv | auth_nopriv | auth_priv ]} {read_view <view_name 32> |
write_view <view_name 32> | notify_view <view_name 32>}
delete snmp group <groupname 32>
show snmp groups
create snmp host <ipaddr> {v1 |v2c | v3 [noauth_nopriv | auth_nopriv | auth_priv]} <auth_string 32>
delete snmp host <ipaddr>
show snmp host <ipaddr>
create trusted_host <ipaddr>
delete trusted_host <ipaddr>
show trusted_host <ipaddr>
enable snmp traps
enable snmp authenticate_traps
show snmp traps
disable snmp traps
disable snmp authenticate_traps
config snmp system contact <sw_contact>
config snmp system location <sw_location>
config snmp system name <sw_name>
enable rmon
disable rmon
33
Allied Telesyn AT-9724TS High-Density Layer 3 Stackable Gigabit Ethernet Switch • Command Line Interface Reference Manual