Figure 49: show module configuration t1 sample output for framing and linecode
Physical connection issue
The
T1 link uses the standard 4 wire link on the RJ-45 connector. Ensure that the physical link
is properly connected. Also make sure that the correct cable type is used: either crossover
cable or straight cable. When connecting to a peer back-2-back, a crossover cable is typically
required. When connecting to a channel-bank or patch-panel, a straight cable is typically
required.
Peer configured as E1
Make sure that the peer you are connected to is a T1 source and not E1. Normally sources
can be configured for both T1 and E1. The Secure Router 2330/4134 can also be configured
for both T1 and E1, but for Release 10.1, voice is not supported on E1 links. Therefore, make
sure both ends are configured for T1.
You can use the show module configuration all command to verify the configuration
for multiple links.
Troubleshooting a SIP Media Gateway problem
318 Troubleshooting August 2013
Comments? infodev@avaya.com