Figure 50: show module configuration all sample output
Remote T1 link reports clock slip or frame drop errors
If the remote T1 link reports a clock slip or that frames are being dropped, see the following
section for troubleshooting.
Incorrect T1/E1 module version
Make sure that the T1/E1 module version is listed as CPLD version 5. Older version 4 cards
can
still be used for data links, but should not be used for voice. New version 5 cards support
both data and voice links.
Use the show version command to display the module version. The following figure shows
a sample output of the command displaying the T1/E1 module versions.
Figure 51: show version sample output for T1/E1 module version
Common problems and solutions