Creation of T1 CAS of addition of PRI link to bundle produces an
error on the state of the slot
The following figure shows sample errors when creating a CAS link or adding a PRI link to a
bundle.
Figure 61: show module t1 sample output with error
The Secure Router 2330/4134 produces these errors when the port in question is on a module
that is shutdown for a hot swap.
See Module LEDs for T1 or BRI are off
on page 323 to troubleshoot a module in the hot swap
state.
Unable to make calls on T1 PRI
If you cannot make calls on a T1 PRI port, see the following sections for troubleshooting
instructions.
Verify the T1 PRI configuration
If
you cannot make calls on a T1 PRI port, make sure that the PRI configuration is correct. The
following is a typical configuration:
config term
interface bundle pri1
link pri_t1 1/1:1-23 voice
isdn
side USR
switch-type primary-5ess
activate
exit 2
Be sure to activate ISDN using the activate
command under isdn (as shown above).
Common problems and solutions