Command fails with invalid interface error
Make sure the interfaces are all non-CPU Ethernet ports using the show bridge
port command.
Verify the interface name is not misspelled.
Verify
both source and destination interfaces are created by executing the show bridge
port command.
Command fails with There is already one analyzer port configured for this
card error
There can not be more than one Analyzer port on each card. Use the show mirror
command to get a list of the configured Monitored and Analyzer ports.
Troubleshooting an operational failure
Traffic is not mirrored
Verify the configuration using the show mirror command.
Verify the port states. Use show bridge port command. All the involved ports must
be in UP state.
Verify the traffic flow (both Tx/Rx) on the source port. Use the show interface
<interface> command.