Variable Value
<module> The module type. Applicable modules are T1, E1, T3, and
CT3. Only modules that are present will be available for
testing.
Ending a BERT test
To end a BERT test, perform the following steps.
Procedure steps
1.
Issue the test command, accompanied by the module type and identifier.
test <module> <identifier>
Example:test t1 6/3
2. Issue the command to end the BERT test.
no bert
Table 14: Variable definition
Variable Value
<identifier> The module identifier.
<module> The module type. Applicable modules are T1, E1, T3, and
CT3. Only modules that are present will be available for
testing.
Resetting to factory defaults
This
procedure describes the steps necessary to reset the Secure Router 2330/4134 to factory
defaults. This command clears all the information stored in NvRam, including user information.
Other major information that will be cleared includes event logs, crash logs, command logs,
and boot parameters.
Procedure steps
1. Enter Configuration Mode.
configure terminal
2. To reset to factory defaults, run the following command:
system reset-to-factory system
Global troubleshooting tasks
48 Troubleshooting August 2013
Comments? infodev@avaya.com