Figure 53: show network-clocks sample output for bad clock source
To change the clock configuration on the Secure Router 2330/4134, use the network-
clock-select command. Then use the show network-clocks
command to verify that
the Secure Router 2330/4134 locks to the clock from the remote peer.
Figure 54: show network-clocks sample output for locking clock source
As shown in the preceding figure, you must wait a period of time for the phase-locked loop
(PLL) to lock to the external clock. It can take anywhere from 30 seconds up to 180 seconds
for the PLL to detect a viable clock source and lock to it.
The following figure shows the clock in locked status.
Common problems and solutions
Troubleshooting August 2013 321