Parameter Descriptions
119
890053-00-02
Manual Torque Boost Setting Details
Code
Description
DRV-16 Fwd Boost
Set torque boost for forward operation.
DRV-17 Rev Boost
Set torque boost for reverse operation.
5.1.7.2 Auto Torque Boost-1
Auto torque boost-1 enables the inverter to automatically calculate the amount of output voltage
required for torque boost based on the entered motor parameters. Because auto torque boost-1
requires motor-related parameters such as stator resistance, inductance, and no-load current, auto
tuning (MOT-11) has to be performed before auto torque boost-1 can be configured. Refer to
section 5.2.5 MOT-11 Auto Tuning on pg, 124.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
DRV
15
Torque boost mode
Torque Boost
1
Auto 1
02
-
MOT
11
Auto tuning
Auto Tuning
3
Rs+Lsigma
03
-
5.1.7.3 Auto Torque Boost 2 (No Motor Parameter Tuning Required)
Auto torque boost-2 does not require Auto Tuning. DRV-23 (ATB Volt Gain) value is used to adjust
the amount of compensation required for each load. It prevents stalls or overcurrent faults at start
up.
Group
Code
Name
LCD Display
Settings
Setting Range
Unit
DRV
15
Torque boost mode
Torque Boost
2
Auto 2
02
-
DRV
22
Auto torque boost
filter gain
ATB Filt Gain
10
1 - 9999
msec
DRV
23
Auto torque boost
voltage gain
ATB Volt Gain
100.0
0 - 300.0
%
Too much torque boost can result in over-excitation and motor overheating. Over current faults
may also occur.