8.2 Application Group 3 (AP3)
8.2.1 Time Event Scheduling
Time Event function enables the inverter to be fully automated. The user can program the inverter
to operate among 4 Time Periods. Each period contains start/stop times for 7 days- 24 hours to
program operation of the inverter. The inverter utilizes the RTC (Real-Time Clock) feature to set
operating times.
To use the Time Event, set the current date and time. Three parameters need to be set to
configure the Time event feature: Time Period Module, Time Event, and Exception Date.
An RTC battery is installed on the I/O CPU board of the H2 inverter and allows for approximately 5 to 6
years of inverter operation.
4 Time period Module types, 8 Time Event Module types, and 8 Exception day types can be used
to configure time events. The Time Event function works based on a series of configuration using
the modules listed in the table above.
8.2.2 AP3 Time Event Parameter List